Product Highlights

  • UL Listed Complete System: Includes UL 448 electric pump, UL 1247 diesel engine, and UL 218 controllers for full compliance.
  • Dual Drive Redundancy: Electric primary pump paired with diesel backup engine ensures continuous operation during power failure.
  • Horizontal Split Case Design: Allows top half removal for maintenance without disturbing piping, reducing downtime and costs.
  • Factory Pre-Assembled Skid: Complete system with integrated piping, valves, and wiring shipped ready for installation.
  • Customizable Material Options: Pump casing, impeller, and shaft available in cast iron, carbon steel, or stainless steel variants.
  • High Flow Capacity: Main pumps support flow rates from 100 to over 5,000 US GPM for diverse fire protection needs.
  • NFPA 20 Compliance: System design strictly adheres to NFPA 20 standards for fire pump installations.
  • Jockey Pressure Maintenance: Integrated jockey pump maintains system pressure to prevent unnecessary main pump cycling.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System

UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System pictures & photos
UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
  • UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
    UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System

Find Similar Products

Product Description

UL Listed Split Case EDJ Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
 

The Split Case EDJ Fire Pump Set is a complete, factory-assembled fire protection system designed for automatic water supply to sprinkler systems, standpipes, fire hydrant networks, and other fixed fire suppression installations. The "EDJ" configuration integrates three pumps(Electric motor primary pump, Diesel engine backup pump, Jockey pressure maintenance pump) into a single skid-mounted package, offering a comprehensive solution with redundant drive options plus pressure maintenance.

All key components-including the electric motor pump, diesel engine, and control panels-are UL Listed under the relevant UL standards, ensuring compliance with NFPA 20 and the highest industry safety requirements.

Electric Fire Pump (Primary) - UL 448 Certified

The primary fire pump is a horizontal split case, double-suction centrifugal pump certified to UL 448 ("Centrifugal Stationary Pumps for Fire-Protection Service"). UL 448 requires that pump casings withstand hydrostatic testing to three times the rated maximum working pressure (or 500 psi, whichever is higher), ensuring robust construction for fire protection duty. The UL 448 performance test mandates that at 100% flow, the pump must meet rated pressure, and at 150% flow, it must deliver at least 65% of rated pressure. The pump is driven by a UL Listed electric motor specifically engineered for stationary fire pump service.

Diesel Engine Fire Pump (Backup) - UL 1247 Certified

The backup fire pump is identical in hydraulic design to the electric pump, ensuring full redundancy with the same flow and head capabilities. It is driven by an industrial diesel engine certified to UL 1247 ("Diesel Engines for Driving Stationary Fire Pumps"). UL 1247 covers all critical aspects of diesel engine construction and performance for fire protection service, ensuring the engine can start and deliver rated power under emergency fire conditions. The diesel engine assembly incorporates NFPA 20-compliant components, including ample space oil tank, engine cooling system, and control system.

Jockey Pump (Pressure Maintenance)

The jockey pump is a small-capacity electric pump(multi-stage vertical or horizontal) that maintains system pressure during non-fire periods, preventing unnecessary starts of the main pumps. Per NFPA 20, the jockey pump head should be set 10-15 meters higher than the main pump cut-in pressure, with standard flow ratings at 25, 50, or 100 GPM.

Control Panels - UL 218 Certified

Both the electric and diesel fire pump controllers are UL 218 Listed(Standard for Fire Pump Controllers). The electric motor controller includes full NFPA 20-required features such as:

  • Across-the-line or reduced-voltage starting

  • Phase reversal and phase loss protection

  • Run indication, power failure alarm, start failure alarm

  • Manual and automatic transfer capability

The diesel engine controller includes:

  • Auto-start on system pressure drop (configurable pressure settings)

  • Full engine monitoring suite: oil pressure, coolant temperature, battery voltage, engine RPM, and run hours

  • Battery charger (UL Listed) with dual starting batteries

  • Overspeed shutdown and pre-alarm functions

  • Weekly exercise timer(programmable)

Horizontal Split Case Pump Design

Both main pumps feature the industry-preferred horizontal split case, double-suction, single-stage centrifugal design, offering superior efficiency, ease of maintenance, and long-term reliability:

  • Double-Suction Impeller: The enclosed double-suction impeller is cast in one piece and hydraulically balanced - practically eliminating axial thrust, reducing vibration, and significantly extending bearing and mechanical seal life.

  • Between-Bearings Design: The impeller is fully supported by bearings on both sides, minimizing shaft deflection, thereby extending packing, seal, and bearing life, while reducing maintenance costs and required floor space.

  • Removable Top Casing Half: The casing splits along the horizontal axis, allowing the top half to be lifted off for full internal inspection - including removal of the impeller, shaft, bearings, and wear rings - without disturbing the suction/discharge piping or pump alignment.

  • Dual Volute Construction (on larger sizes): Gradually reduces radial thrust load, improving operational stability and component longevity.

Packaged Skid - Factory Pre-Assembled

The complete system is pre-assembled on a heavy-duty steel base frame(skid-mounted) with integrated vibration isolators and flexible couplings. The skid includes:

  • Common suction header with combined system inlet connection

  • Individual isolation and check valves for each pump

  • Common discharge header with main fire protection system connection

  • Complete piping, supports, and flanges between components

  • Pressure gauges and pressure sensors/transducers

  • All necessary wiring between controllers and drives completed at factory before shipment

Hydraulic Performance Guarantees

Performance parameters of the system are subject to the specific requirements of the intended system application. All UL Listed fire pump sets are 100% factory hydrostatically and performance tested before shipment. A certified test report is provided with each unit, documenting compliance with UL 448 acceptance criteria.

Key Design Features

  • Horizontal Split Case Casing: Axially split casing design allows removal of the top half without disturbing piping, simplifying field maintenance.

  • Double-Suction Impeller: Single- or two-stage configuration, dynamically balanced, cast in corrosion-resistant bronze.

  • Heavy-Duty Shaft with Protective Sleeve: High-strength alloy steel shaft with replaceable stainless steel sleeve to protect against corrosion and wear.

  • Interchangeable Grease-Lubricated Bearings: Heavy-duty, grease-lubricated radial and thrust bearings for extended service life.

  • Mechanical Seal / Gland Packing: Standard mechanical seal(carbon/ceramic or silicon carbide); robust gland packing also available by request.

Technical Specifications

 
 
Parameter Range / Options
Flow Rate(Main Pumps) 100 - 5,000+ US GPM(custom)
Total Head 40 - 355+ PSI(3 - 20+ bar)
Design Pressure Class Ratings ANSI / ASME class 150, 250, 300
Speed 1750 / 3500 RPM(electric) / 1450-1800 RPM(diesel)
Electric Motor Power 30 - 600 HP(custom, UL Listed)
Diesel Engine Power 60 - 750+ HP(custom, UL 1247 certified)
Jockey Pump Flow 10 - 100 GPM(standard), sized to system leakage
Jockey Pump Head Set 10-15 m higher than main pump cut-in pressure
Flange Standards ANSI Class 125 / 150 / PN16(custom)
Sealing Type Mechanical seal or gland packing
Base Frame Heavy-duty steel skid with vibration isolators
Rotation Clockwise or counter-clockwise(selectable)
Certification UL Listed(components); design based on NFPA 20

Material Options

 
 
Component Standard Material Optional Material
Pump Casing Ductile iron(NFPA 20/UL preferred) Cast iron / Carbon steel / SS304
Impeller Bronze(ASTM B584 UNS C83600) SS304 / SS316 / Duplex
Shaft High-strength alloy steel(AISI 4340 / 40Cr) SS304 / SS316
Wear Rings Bronze SS304 / SS316
Shaft Sleeve SS304 SS316 / Super Duplex
Mechanical Seal Carbon / Ceramic Silicon carbide / Tungsten carbide
Casing Coating Epoxy primer / RAL 3000 red Custom color

Applications

  • Automatic sprinkler systems: Wet pipe, dry pipe, pre-action, and deluge systems

  • Standpipe systems: Class I, II, and III risers for high-rise buildings

  • Fire hydrant networks: Municipal and industrial water supply systems

  • Commercial buildings: Hotels, shopping centers, office towers, hospitals

  • Industrial facilities: Factories, warehouses, chemical plants, power generation

  • Oil and gas facilities: Refineries, petrochemical plants, storage terminals

  • Infrastructure: Airports, seaports, railway hubs, tunnels

  • High-risk occupancies: Data centers, pharmaceutical manufacturing, large commercial complexes

  • Marine and offshore: Fire protection for ships and oil rigs(ABS certification available by request)

Operating Conditions

  • Maximum fluid temperature: 105°C(221°F)

  • Maximum ambient temperature: Up to +40°C(standard); higher with engine derating

  • Maximum working pressure: Up to 355 PSI(25 bar), depends on configuration

  • NPSHr: Low NPSH characteristic due to double-suction impeller design

 

Product Attributes

 
 
Parameter Specification
Product Type EDJ Fire Pump Set(Electric + Diesel + Jockey)
Certification UL Listed(UL 448, UL 1247, UL 218)
NFPA Compliance NFPA 20(design)
Pump Type Horizontal split case, double suction, single-stage
Flow Range 100 - 5,000+ US GPM
Head Range 40 - 355+ PSI
Primary Driver UL Listed electric motor
Backup Driver UL 1247 diesel engine
Jockey Pump Driver Electric motor
Pump Casing Ductile iron(standard) / Cast iron / SS(optional)
Impeller Bronze(standard) / SS304 / SS316 / Duplex(optional)
Flange Standard ANSI Class 125 / 150(default) / PN16 / Custom
Base Frame Heavy-duty steel skid with drip lip
Electric Controller UL 218 Listed with full NFPA 20 features
Diesel Controller UL 218 Listed with engine monitoring & auto-start
Pressure Switches Included for auto-start sequencing
Gauges Suction & discharge pressure gauges included
  • Valves: Isolation gate valves, check valves, air release valves included

  • Piping: Common suction & discharge headers, flexible couplings included

  • Testing: 100% factory hydrostatic and performance tested with full documentation

  • Configuration: Factory-assembled and pre-wired skid

  • Design Standards Referenced: NFPA 20(system), UL(component)

Specification Table

 
 
Component / Parameter Specification
Electric Pump Driver UL Listed electric motor(NEMA / IEC), ODP/TEFC enclosure
Diesel Pump Driver UL 1247 certified industrial diesel engine(Deutz / Yuchai)
Jockey Pump Driver Electric motor
Flow Rate - Main Pumps 100 - 5,000+ US GPM(customer specified)
Total Head 40 - 355+ PSI(customer specified)
Pump Casing Material Ductile iron(standard) / Cast iron / Carbon steel / SS
Impeller Material Bronze(standard) / SS304 / SS316 / Duplex
Flange Standard ANSI Class 125 / 150(default)
Base Frame Heavy-duty steel channel with drip lip & vibration isolators
Pressure Rating ANSI class 150 / 250 / 300
Electric Controller UL 218 Listed(microprocessor-based)
Diesel Controller UL 218 / UL 508A Listed with engine monitoring
Auto-Start Function Pressure drop starts main pump; power failure starts backup diesel
Weekly Exercise Timer Programmable for diesel engine routine testing
Battery Charger UL Listed, automatic dual battery charger
Pressure Vessel Optional, per system design
Operation Mode Automatic(pressure-drop) / Manual / Test
Certification UL Listed(core components)


UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System
Pump

 

 
  1. UL listed fire pump set

  2. split case EDJ fire pump

  3. electric and diesel fire pump

  4. NFPA 20 fire pump skid

  5. horizontal split case double suction pump

  6. UL 448 electric fire pump

  7. UL 1247 diesel fire pump

  8. UL 218 fire pump controller

  9. packaged fire pump system with jockey pump

  10. 2000 gpm UL fire pump

  11. UL FM fire fighting pump skid

  12. dual drive fire pump set


COMPANY PROFILE 
We are an active and successful manufacturer/exporter in the fire fighting industry in China. We combine good quality products with competitive prices and efficient services. In this way, Synergy has exported products to more than 50 countries all over the world. Our intelligent sales & technical teams are always ready to provide expertise services for any inquiries from clients. 
Joining Synergy and sharing the bright future together. 


COMPANY IDEOLOGY
We exist because of our customers.

We exist to provide our customers with superior products at a competitive price while generating a reasonable profit for our company and our agents. 

Quality comes first, second, and last .Always be able to say that we've done not only our best, but THE best. 

We are proud of being a team that Integrity and honesty are the key characteristics in the personality of the company 

We are committed to be the carrier in which our employees are treated with equal respect and value to enable them to thrive and reach their full potential. 


COMPANY SPIRIT:
As the name implies, SYNERGY wants to understand your needs and to satisfy them with you, at your conditions and for your benefit.



UL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection SystemUL Listed Split Case Edj Fire Pump Set-Electric Motor+Diesel Engine+Jockey Pump-Mounted Fire Protection System



 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR266542". Items marked "verified" are certified.

Watch Video
Watch Video
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.

About Our Factory & Business Background

Address
B-1901, Tianyuangang Center, No. 2 East Third Ring North Road, Chaoyang District, Beijing, China
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
CIF, CFR, EXW, FOB
verified Average Lead Time
Peak Season Lead Time: within 15 workdays, one month
Off Season Lead Time: within 15 workdays, one month
verified Nearest Port
Tianjin Port, Ningbo Port, Shanghai Port, Qingdao Port

Our Production Capability & Technical Expertise

Main Products
Fire Extinguisher, Fire Hose, Fire Hose Reel and Cabinet, Fire Fighting Equipment, Fire Sprinkler System, Fire Pump Set, Fire Suits, Fire Hose Fitting
verified ODM Service Available
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2008-07-15
Export Year
2003-03-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
verified Number of Foreign Trading Staff
10
verified Overseas Agent/Branch
No

FAQ

What certifications does this fire pump set hold?
The system is UL Listed with UL 448 for the electric pump, UL 1247 for the diesel engine, and UL 218 for the controllers, ensuring full compliance with NFPA 20.
Can the pump materials be customized?
Yes, the pump casing, impeller, and shaft can be customized to materials such as cast iron, carbon steel, or various stainless steel grades like SS304 and SS316.
What is the maximum flow rate of the main pumps?
The main pumps offer a customizable flow range from 100 to over 5,000 US GPM, tailored to specific system requirements.
How does the system handle power failures?
The system features a diesel engine backup pump that automatically starts upon power failure or pressure drop, ensuring continuous water supply.
Is the system pre-assembled before shipment?
Yes, the entire unit is factory pre-assembled on a heavy-duty steel skid with all piping, valves, and wiring completed prior to shipment.
What is the lead time for this product?
The average lead time is within 15 workdays or one month, regardless of whether it is peak or off-peak season.
Does the system include a jockey pump?
Yes, it includes a jockey pump designed to maintain system pressure during non-fire periods, preventing unnecessary starts of the main pumps.
What are the available flange standards?
Standard flanges are ANSI Class 125 or 150, but custom options including PN16 are available upon request.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs