Product Highlights

  • UL & FM Certified Safety: All critical components are UL Listed and Factory Mutual Approved for code compliance.
  • Residue-Free Protection: CO2 leaves no residue, ideal for sensitive electrical equipment and valuable assets.
  • Custom Engineered Design: Systems are custom-engineered using hydraulic software for precise agent delivery.
  • Versatile Application Modes: Available in Total Flooding, Local Application, and Hand-Hose Line configurations.
  • High Pressure Efficiency: 14.7 MPa working pressure ensures rapid fire suppression in 20-60 seconds.
  • Environmentally Sustainable: Zero ODP and low GWP; uses recycled CO2 without depleting stratospheric ozone.
  • Wide Hazard Coverage: Protects marine, power generation, data centers, and industrial manufacturing hazards.
  • Advanced Detection Control: UL 864 listed panel with cross-zone smoke, heat, and flame detection capabilities.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application

UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application pictures & photos
UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
  • UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
    UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application

Find Similar Products

Product Description

UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
 

This UL Listed High Pressure Carbon Dioxide (CO2) Fire Suppression System is an engineered fixed fire protection solution designed in full compliance with NFPA 12: Standard on Carbon Dioxide Extinguishing Systems - the internationally recognized standard for CO2 fire protection installation and design. All critical system components are UL Listed and Factory Mutual (FM) Approved, with UL listed releasing panels (UL 864) and detection devices (UL 268, UL 521) ensuring system integrity and code compliance.

Carbon dioxide (CO2) is the original "clean agent" - a colorless, odorless, electrically non-conductive gas that suppresses fire by rapidly displacing oxygen and removing heat through expansion cooling. CO2 leaves no residue and requires no cleanup, making it ideal for protecting sensitive electrical equipment, mechanical hazards, and valuable assets where water or dry chemical agents could cause damage.

The system is available with three application configurations: Total Flooding (for unoccupied enclosed spaces), Local Application (directed at specific hazards), or Hand-Hose Line (manual suppression). Each system is custom-engineered using hydraulic flow calculation software to ensure precise agent delivery based on hazard volume, fire class (A / B / C), and design concentration requirements.

Applications:

CO2 fire suppression systems are widely used to protect normally unoccupied or intermittently occupied high-risk hazards including:

  • Marine & Offshore: Engine rooms, pump rooms, machinery spaces, cargo holds, boiler rooms - IMO SOLAS-aligned protection for propulsion and auxiliary machinery spaces

  • Power Generation & Utilities: Turbine enclosures, generator rooms, transformer rooms, power transmission rooms, switchgear rooms

  • Electrical Hazards: Switch rooms, control cabinets, electrical panels/motor control centers, high-voltage chambers, cable galleries

  • Industrial & Manufacturing: Paint spray booths, dip tanks, printing presses, industrial process equipment, flammable liquid storage areas, dust collectors, rolling mills, coating machines

  • Data Centers & IT Infrastructure: Servers, networking equipment, control rooms (requires unoccupied/non-continuous human exposure - for staffed areas, consider NFPA 2001 clean agents)

  • Special Hazards: Industrial laboratories, CNC machines, fume hoods, archives, vaults, solvent recovery systems, engine test cells, battery rooms

Component List:

 
 
Component Description
CO2 Storage Cylinders High pressure (14.7 MPa working pressure @ 21°C), DOT-3AA / ISO 9809 certified, individual capacities 16-54 kg (35-120 lb) with cylinder racks
Cylinder Valves UL-listed, with pressure gauge, rupture disc/frangible disc protection, handwheel or pneumatically operated
Manifold Assembly Common piping connecting multiple cylinders for simultaneous discharge with integrated check valves to prevent backflow
Flexible High-Pressure Hoses Connect cylinder valves to manifold, accommodating thermal expansion and vibration
Actuators (Pilot) Nitrogen cylinder (5.9 MPa) or electric solenoid actuation (UL 429/429A Recognized Component) for automatic valve release
Selector Valves Direct agent flow to specific hazard zones in multi-area systems
Discharge Piping High pressure schedule 80 seamless steel pipe with threaded fittings or flanged connections
Discharge Nozzles Precision-engineered orifices providing uniform CO2 distribution throughout the hazard(axial flow / radial flow types for total flooding, directional types for local application)
Detection & Control Panel UL 864 (UUKL) listed releasing panel with cross-zone smoke/heat/flame detection (UL 268/UL 521)
Alarm Devices Audible(horn/strobe) and visual alarms for pre-discharge warning
Abort Switch / Lockout Valve Manual stop device to delay or prevent system discharge (for testing, maintenance, or unintended fire alarms)
Pressure Switches / Pressure Transducers Post-discharge agent flow verification; optional DIMES digital monitoring system for real-time cylinder content verification

Technical Specifications:

 
 
Parameter Specification
System Type High Pressure Carbon Dioxide (CO2) Fire Suppression - Engineered System
Applicable Standards NFPA 12 (latest edition) - Standard on Carbon Dioxide Extinguishing Systems
Certification UL Listed, FM Approved
Extinguishing Agent Carbon Dioxide (CO2) - residue-free, non-conductive, non-corrosive
Design Concentration 34-40 % v/v CO2 for surface fires (Class B / C); higher for Class A deep-seated
Cylinder Working Pressure 14.7 MPa (≈2,130psi) @21°C(70°F)
Cylinder Test Pressure 25.5MPa (≈3,698psi)
Cylinder Standards DOT-3AA / ISO 9809 / ISO 11118
Individual Cylinder Capacity 16kg (35lb), 25kg (55lb), 35kg (77lb), 45kg (99lb), 54kg (120lb) - custom multiples
Actuation Options Electric (solenoid valve), Pneumatic (N2 pilot cylinder), Mechanical (pull lever), or Combined
Actuator Specifications UL 429 / UL 429A Recognized Component - direct-acting solenoid valve for pilot release
Discharge Time 20-60 seconds (based on hazard volume)
Operating Temperature −10°C to +50°C(14°F to 122°F)
Piping Schedule 80 seamless steel, threaded or flanged connections
Detection Types Smoke (UL 268), Heat (UL 521), Flame, or Cross-Zone detection
Control Panel UL 864 (UUKL) listed - releasing panel with pre-alarm, time delay, abort circuit
Optional Real-Time Monitoring Digital measurement system (DIMES) for continuous CO2 cylinder content monitoring (not UL listed option)
Refill Agent Availability Readily available at CO2 filling stations worldwide - low cost, easy access
Ozone Depletion Potential (ODP) 0 (zero) - environmentally sustainable
Global Warming Potential (GWP) 1 (uses recycled/industrial CO2 - not drawn from fossil sources; does not deplete stratospheric ozone)

Certifications Compliance:

 
 
Standard / Body Requirement
UL (Underwriters Laboratories) Component certification: UL 864 (Control Panels), UL 268(Smoke Detectors), UL 521(Heat Detectors), UL 429/429A(Solenoid Actuators), UL Listed Pressure Cylinders (DOT-3AA compliance referenced)

UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application


UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application


 
Introduction
Carbon Dioxide Gas
Under normal atmospheric temperature and pressures, carbon dioxide exists as a colorless, odorless gas which is about 1.5 times heavier than air. Carbon dioxide will not burn or support combustion and will not sustain life. When confined within a suitable pressure vessel and depending on temperature and pressure conditions, carbon dioxide can exist in any of three stages of matter; solid, liquid and gas.
 
High Pressure Carbon Dioxide System
High pressure CO2 system is a specialized fire extinguishing system designed to maintain the carbon dioxide supply at 21º C and 850 psig in strength alloy steel cylinders. The cylinders contain the CO2 required to protect the largest single hazard. On large hazards where several cylinders are required, a manifold is used to connect each cylinder by means of flexible hoses and check valves. Cylinder valves control the CO2 flow to the hazard through properly sized pipe, terminating in nozzles that apply the CO2. Flow rate is controlled by nozzle orifices as well as pipe sizes. The cylinder master valves are electronically operated and the slave valves are pressure actuated. The master valves can be automatically and/or manually operated.
 
CO2 Extinguishing System Most Ideal For Protecting
 

Available Cylinder Valves:UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application
system
  1. UL listed CO2 fire suppression system

  2. high pressure carbon dioxide extinguishing system

  3. NFPA 12 compliant CO2 system

  4. total flooding CO2 fire suppression

  5. local application CO2 system

  6. marine CO2 fire protection system

  7. electrical panel CO2 suppression

  8. generator room fire suppression

  9. CO2 system for data center

  10. engineered carbon dioxide fire system

  11. UL FM CO2 flooding system

  12. CO2 fire suppression for industrial hazards



COMPANY PROFILE 
We are an active and successful manufacturer/exporter in the fire fighting industry in China. We combine good quality products with competitive prices and efficient services. In this way, Synergy has exported products to more than 50 countries all over the world. Our intelligent sales & technical teams are always ready to provide expertise services for any inquiries from clients. 
Joining Synergy and sharing the bright future together. 


COMPANY IDEOLOGY
We exist because of our customers.

We exist to provide our customers with superior products at a competitive price while generating a reasonable profit for our company and our agents. 

Quality comes first, second, and last .Always be able to say that we've done not only our best, but THE best. 

We are proud of being a team that Integrity and honesty are the key characteristics in the personality of the company 

We are committed to be the carrier in which our employees are treated with equal respect and value to enable them to thrive and reach their full potential. 


COMPANY SPIRIT:
As the name implies, SYNERGY wants to understand your needs and to satisfy them with you, at your conditions and for your benefit.

UL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local ApplicationUL Listed CO2 Fire Suppression System-High Pressure Engineered Carbon Dioxide System-Total Flooding & Local Application

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR266542". Items marked "verified" are certified.

Watch Video
Watch Video
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.

About Our Factory & Business Background

Address
B-1901, Tianyuangang Center, No. 2 East Third Ring North Road, Chaoyang District, Beijing, China
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
CIF, CFR, EXW, FOB
verified Average Lead Time
Peak Season Lead Time: within 15 workdays, one month
Off Season Lead Time: within 15 workdays, one month
verified Nearest Port
Tianjin Port, Ningbo Port, Shanghai Port, Qingdao Port

Our Production Capability & Technical Expertise

Main Products
Fire Extinguisher, Fire Hose, Fire Hose Reel and Cabinet, Fire Fighting Equipment, Fire Sprinkler System, Fire Pump Set, Fire Suits, Fire Hose Fitting
verified ODM Service Available
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2008-07-15
Export Year
2003-03-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
verified Number of Foreign Trading Staff
10
verified Overseas Agent/Branch
No

FAQ

What certifications does the CO2 system have?
The system is UL Listed and Factory Mutual (FM) Approved, with components meeting UL 864, UL 268, UL 521, and UL 429 standards.
Is the system customizable for specific hazards?
Yes, each system is custom-engineered using hydraulic flow calculation software to ensure precise agent delivery based on hazard volume and fire class.
What are the available application configurations?
The system is available in three configurations: Total Flooding for unoccupied enclosed spaces, Local Application for specific hazards, and Hand-Hose Line for manual suppression.
How long does the discharge process take?
The discharge time is typically 20-60 seconds, depending on the hazard volume and system design.
Is the CO2 agent environmentally friendly?
Yes, it has an Ozone Depletion Potential (ODP) of 0 and a Global Warming Potential (GWP) of 1, using recycled or industrial CO2.
What types of hazards can this system protect?
It protects marine engine rooms, power generation facilities, data centers, industrial manufacturing areas, and other high-risk electrical or flammable liquid hazards.
What actuation options are available?
Actuation options include Electric (solenoid valve), Pneumatic (N2 pilot cylinder), Mechanical (pull lever), or Combined actuation methods.
Does the system require cleanup after discharge?
No, CO2 is a clean agent that leaves no residue and requires no cleanup, making it safe for sensitive equipment.